Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE
Sort By:
1 2 3 ... 8
Coleman 233896608 SJEW Electrical Cable Coleman 601266607 SPT-2 Lamp Cord Barostat 553056607 Solid Type CL-2 Thermostat Cable
For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved.
Romex SIMpull 12/3UF-WGX250 Type UF-B Building Wire Armolite 68583423 Solid Metal Clad Cable Romex SIMpull 12/3UF-WGX50 Type UF-B Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Armolite 68580023 Solid Metal Clad Cable Armorlite 68580001 Type MC Armored Cable Romex SIMpull 10/3UF-WGX250 Type UF-B Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 14/2UF-W/GX250 Building Wire Romex SIMpull 12/2UF-WGX100 Building Wire Romex SIMpull 10/2UF-WGX50 Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 10/2UF-WGX100 Type UF-B Building Wire Southwire 12YEL-SOLX500 Solid Single Building Wire Romex SIMpull 10/3UF-W/GX100 Type UF-B Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 10/3NM-WGX50 Building Wire Romex SIMpull 14/3NM-WGX25 Building Wire Romex SIMpull 10/3NM-WGX100 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire 8SOLX500BARE Solid Electrical Wire Southwire 6SOLX315BARE Solid Electrical Wire Southwire 6GRN-STRX500 Stranded Single Building Wire
Equipment and circuit grounding. Equipment and circuit grounding. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed.
Southwire 8BLK-STRX500 Stranded Single Building Wire Southwire 14BK-STRX500 Stranded Single Building Wire Southwire 14GRN-STRX500 Stranded Single Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
Southwire 12GRN-STRX500 Stranded Single Building Wire Southwire 10WHT-STRX500 Stranded Single Building Wire Southwire 10GRN-STRX500 Stranded Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed.
Southwire 6STRDX315BARE Stranded Electrical Wire Romex SIMpull 12/2NM-WGX250 Building Wire Romex SIMpull 12/2UF-W/GX250 Building Wire
Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
   
 
1 2 3 ... 8